Programming Outline

Each system installed will require programming. Most installations
being performed by the professional alarm installer for a specifi c
organization will have common values set in every Control Panel
reporting to the same Central Station. Other programming values,
such as the account number and sensor setup, will be unique for
each installation.
Following is an outline to guide the professional alarm installer
through the programming of the Control Panel.
If you don't read anything else, read this outline!
Use the following outline in conjunction with this copy of the
Installation and Programming Instructions to guide you through
the installation.
Because of the many programming options available with this
Control Panel, thoroughly reading this manual is very important.
Understanding the Control Panel's programming structure will help
to save time during each installation.
At this stage, all the wireless and hardwired sensors should be
installed, and the Control Panel should be mounted, connected,
and powered-up.
1. Start at the Home Screen.
2. Press the logo at the lower right corner of the screen.
(The Installer Toolbox can also be accessed via
the third screen of the System Toolbox.)
3. Enter the Installer Code (default = 1561) to display the Installer Toolbox.
4. Press SYSTEM CONFIGURATION and begin
programming as described on Page 18.
5. USE THE INSTALLATION LOG SHEET TO RECORD
PROGRAMMED VALUES FOR THE SYSTEM.
6. After setting all the required programming values for the sensors and
the Control Panel, press END, then EXIT, to save the changes.
7. After the Control Panel restarts, press SECURITY, MENU,
TOOLBOX, enter the Master User Code (default = 1111), press
USER MANAGEMENT and setup the user's codes. Be sure to
set a Duress Code as User #8. Press BACK when fi nished.
8. Press BRIGHTNESS / VOLUME and set the levels for the installation.
The volume setting DOES NOT affect the volume of alarm sounds.
9. Press ➜ to view the second toolbox screen.
10. Press BACKLIGHT TIMEOUT and set the display lighting timeout.
11. Press SET DATE and SET TIME and set the calendar and clock. (If the
GSM module is installed, the date and time are set automatically.)
12. Press the
button to return to the Home Screen.
After all setup and programming, refer to the Operation and
User's Guide for details on operating the system. Check off the
programmed options for the system in the User's Guide.
Be sure to instruct the subscriber on the proper operation of the
system, and leave the User's Guide at the installation site for
reference.

SIA CP-01 Defaults

Several system programmable options have the defaults pre-set to
provide compliance with the Security Industry Association CP-01
Standard. All other system settings and functions that are required
to comply with SIA CP-01 are permanently programmed into
the Console and cannot be changed. Refer to the table for each
programmable option that has a required SIA CP-01 programming
default.
16
Press logo to access
the Installer Toolbox
Figure 45. The Home Screen
Installer Toolbox can be
accessed here also
Figure 46. Toolbox Screen Three
Figure 47. Installer Toolbox Screen
Figure 48. System Confi guration Question "Q-1"
PROGRAMMING QUESTION
Q-1 Wireless Sensor Dialer Delay
Q-2 Wired Sensor Dialer Delay
Q-5 Exit Delay
Q-6 Entry Delay #1
Q-7 Entry Delay #2
Q-10 Call Waiting Disable Code
Q-20 Swinger Shutdown Count
Q-26 Auto Stay
Q-27 Exit Delay Restart
Q-31 Cancel Time
Q-32 Cancel Display
Q-35 Abort Window Dialer Delay
Q-78 Select Output
SIA CP-01 DEFAULT
RANGE
30 Seconds
On or Off
30 Seconds
On or Off
60 Seconds
45-120 Seconds
30 Seconds
30-240 Seconds
45 Seconds
30-240 Seconds
No Default Code
0-6 Digits
2 Trips
1-6 Trips
Enabled
Enabled or Disabled
Enabled
Enabled or Disabled
5 Minutes
6-254 Minutes
Enabled
Enabled or Disabled
30 Seconds
15 or 45 Seconds
Follows Internal Sounder
See Q-78 for Options