Q-84 Select services require master
code (0-1)
DEFAULT: Disabled (0)
The Services button can be configured to require
the use of the Master User Code to access Services.
•
The default (0) disables the requirement for
the Master User Code to access the Services
menu.
•
To require the use of the Master User Code to
access the Services menu, select enabled (1).
When enabled then the Master User Code is
required to access the Services and the Z‐wave
device configurations. This keeps unauthorized
users from being able to change Z‐wave settings,
such as temperature, lights and locks.
Q-85 Select master user access to
z-wave toolbox (0-1)
DEFAULT: Disabled (0)
The Z‐Wave Toolbox menu can be set to require the
use of the Master User Code or the Installer Code.
By default, the Installer Code is required for users
to access the Z‐Wave Toolbox.
•
The default (0) requires the use of the Installer
Code to access the Z‐Wave Toolbox menu and
all of its features, including the Advanced
Toolbox.
•
To require the use of the Master User Code or
the Installer Code to access the Z‐Wave Tool
box menu, select enabled (1).
NOTE:
When enabled (1) the Installer code will
still be required to access the Advanced
Toolbox menu. This prevents end users
from adding or removing Z‐Wave devices.
Q-86 Select disable siren after two-
way audio (0-1)
DEFAULT: Disabled (0)
This setting enhances system operation in personal
emergency applications and also provides the
dealer with the option of the siren sounding until
the bell cut off or to the end of a two‐way‐voice
session.
•
The default (0) will cause the siren to resume
after two‐way audio (if the bell cut off timer
has not expired).
•
Enable (1) will cause the siren to shut off after
a two‐way audio session.
Control Panel Programming Questions
Q-87 Select keyfob/remote arming
mode on system not ready (0-2)
DEFAULT: Auto bypass with zone
participation on restore (0)
This setting controls how the system will react
when there are open sensors and the system is
armed remotely.
•
The default (0) will automatically bypass all
sensors that are open when the system is
armed remotely. If a sensor restores while the
system is armed, the sensor's bypass will be
removed, and the sensor will be ready to
trigger an alarm.
•
To automatically bypass all sensors that are
open when the system is armed remotely, and
keep all bypasses in place during the arming
cycle, even if a sensor restores, select auto‐
bypass (1).
•
To prevent arming remotely when any sensor
is open, select arm only when ready (2).
Q-88 Select siren mode (0-1)
DEFAULT: Sound for burglary and fire/
CO (0)
This setting selects which alarm types will activate
a Z‐Wave siren linked to the system.
•
The default (0) will cause a Z‐Wave siren to
sound during burglary and fire/CO alarms.
•
To have a Z‐Wave siren sound only during
burglary alarms, select sound for burglary only
(1).
Q-89 Select allow backlight always
on (demo mode) (0-1)
May cause ghost / image retention
NOTE:
DEFAULT: Disabled (0)
When enabled (1) allows the customer to program
the "always on" option for backlight programming.
Due to a small percentage of image "ghosting" on
the panel (because the backlight never goes off),
this question was been created but has been
defaulted to (0) disabled.
©2013 2GIG Technologies Inc. All Rights Reserved.