Q-64 Select smart test reports
DEFAULT: Disabled (0)
Smart test reports are a way to reduce Central
Station traffic. If smart test reports are enabled and
regular periodic test reports are enabled, any non‐
test report to the Central Station (alarm, restore,
trouble, etc.) during the normal operation of the
system will reset the periodic test report timer.
Periodic test reports would only be sent if the
Control Panel has not reported in any way to the
Central Station.
•
The default (0) prevents smart test reports.
•
To allow smart test reports, select enabled (1).
Q-65 Select RF jam causes trouble
(0-1)
DEFAULT: Disabled (0)
The system can monitor the Control Panel's sensor
receiver and detect whether a transmitter is stuck
on the air causing jamming. When jam detect is
enabled, the Control Panel will indicate a trouble
condition if RF jamming is detected.
This programming question only
NOTE:
functions if trouble reports are enabled
with programming question Q‐50.
•
The default (0) disables RF jam detection.
•
To turn on RF jam detection, select enabled
(1).
Q-66 Select daylight saving (0-1)
DEFAULT: Enabled (1)
The Control Panel can adjust its displayed clock and
internal clock for daylight saving time. If the cell
radio is used, the time will be automatically
adjusted regardless of this setting. The system
default is set for post 2007 daylight saving
changeover dates. These dates can be modified in
case the daylight saving changeover date moves
again.
•
The default (1) enables daylight saving time
adjustment.
•
To turn off automatic daylight savings adjust,
select disabled (0).
If required, use programming questions
NOTE:
Q‐67, Q‐68, Q‐69, and Q‐70 to modify the
daylight saving start and stop dates.
52
©2013 2GIG Technologies Inc. All Rights Reserved.
Q-67 Select daylight saving start
month (01-12)
DEFAULT: March (03)
•
The default (03) sets March as the daylight
saving start month.
•
To change the start month, enter the month,
January ‐ December (01‐12), that the new
daylight saving time will start.
Q-68 Select daylight saving start
Sunday (1-7)
DEFAULT: 2nd Sunday (2)
•
The default (2) sets the second Sunday as the
daylight saving start week.
•
To change the start week, enter the 1st, 2nd,
3rd, 4th, last, second from last, third from last
(1‐7) as the daylight saving start week.
Q-69 Select daylight saving end
month (01-12)
DEFAULT: November (11)
•
The default (11) sets November as the daylight
saving end month.
•
To change the end month, enter the month,
January ‐ December (01‐12), that the custom
daylight saving time will end.
Q-70 Select daylight saving end
Sunday (1-7)
DEFAULT: 1st Sunday (1)
•
The default (1) sets the first Sunday as the
daylight saving end week.
•
To change the end week, enter the 1st, 2nd,
3rd, 4th, last, second from last, third from last
(1‐7) as the daylight saving end week.
Q-71 Select system tamper causes
trouble (0-1)
DEFAULT: Enabled (1)
A tamper switch on the Control Panel detects if the
case has been opened. The system can be
programmed so that a tamper switch activation will
cause a trouble indication if the system is disarmed,
and an alarm if the system is armed.
•
The default (1) allows the Control Panel
tamper switch to trigger trouble when the
system is disarmed, and alarm when the
system is armed.