has been reached or the system is disarmed. If 
alarm restores are enabled and swinger shutdown 
is set to two, a restore will be reported if the sensor 
is closed (normal state) at bell cutoff or becomes 
closed after bell cutoff. If swinger shutdown is set 
to one, a restore will only be sent if the sensor is 
closed at the time of disarm. Restores are not sent 
if a sensor is in swinger shutdown until the time of 
disarm and the sensor is closed.
The default (0) prevents alarm restore reports.
To allow alarm restore reports, select enabled 
(1).
Q-58 Select trouble restore reports
to CS (0-1)
DEFAULT: Enabled (1)
Trouble restore reports can be sent to the Central 
Station when any sensor trouble condition clears.
The default (1) allows trouble restore reports.
To turn off trouble restore reports, select 
disabled (0).
Q-59 Select bypass restores reports
to CS (0-1)
DEFAULT: Disabled (0)
Bypass restore reports can be sent to the Central 
Station when any sensor that was force bypassed 
or manually bypassed gets restored.
The default (0) prevents bypass restore 
reports.
To allow bypass restore reports, select enabled 
(1).
Q-60 Select AC restore reports to
CS (0-1)
DEFAULT: Enabled (1)
AC power restore reports can be sent to the Central 
Station when the Control Panel regains AC power 
after an AC power loss.
The default (1) allows AC power restore 
reports.
To turn off AC power restore reports, select 
disabled (0).
NOTE:
The AC power will have to be restored 
to the Control Panel for one minute 
before the AC power loss trouble alert 
 automatically clears. If programming 
question Q‐39 is enabled, the actual AC 
power restore report will occur at a 
Control Panel Programming Questions
random time of up to four hours after the 
AC power loss trouble alert 
cleared.
The Control Panel's AC power icon 
NOTE:
displays the power status. A red "X" over 
the icon indicates no AC power.
Q-61 Select system low battery
restore reports to CS (0-1)
DEFAULT: Enabled (1)
Control Panel low battery restore reports can be 
sent to the Central Station if the Control Panel 
battery had tested low and is now Ok.
The default (1) allows Control Panel low 
battery restore reports.
To turn off Control Panel low battery restore 
reports, select disabled (0).
Q-62 Select RF low battery restores
reports to CS (0-1)
DEFAULT: Enabled (1)
Sensor low battery restore reports can be sent to 
the Central Station if a sensor battery had tested 
low and is now Ok.
The default (1) allows sensor low battery 
restore reports.
To turn off sensor low battery restore reports, 
select disabled (0).
Q-63 Select phone fail detect (0-1)
DEFAULT: Disabled (0)
The system can monitor the telephone line 
connected to the Control Panel. If the telephone 
line is shorted or cut, the Control Panel will indicate 
telephone line trouble by sounding trouble beeps 
and displaying the no‐phone icon.
If the optional cell radio modem is installed, the 
telephone line failure will still be reported if this 
question is enabled.
The default (0) disables this feature.
To turn on this feature, select enabled (1).
If the dialer is disabled with 
NOTE:
programming question Q‐8, telephone 
line failure detection is also disabled 
regardless of the setting of this 
programming question.