CDRs (media and SIP signaling) sent in Syslog messages. For CDRs sent in Syslog
messages, you can customize the name of the CDR field. The table lets you configure
up to 128 Syslog CDR customization rules.
CDRs related to RADIUS accounting and sent in RADIUS accounting request
messages. For RADIUS accounting CDRs, you can customize the RADIUS Attribute's
prefix name and RADIUS Attribute's ID, for standard RADIUS Attributes and vendor-
specific RADIUS Attributes (VSA). For example, instead of the default VSA name,
"h323-connect-time" with RADIUS Attribute ID 28, you can change the name to "Call-
Connect-Time" with ID 29. The table lets you configure up to 40 RADIUS-accounting
CDR customization rules. For more information on RADIUS accounting, see
Configuring RADIUS Accounting on page 779.
If you do not configure a CDR customization rule for a specific CDR, the device generates
the CDR in a predefined default CDR format (see CDR Field Description on page 761).
Notes:
The following standard RADIUS Attributes cannot be customized: 1 through 6, 18
through 20, 22, 23, 27 through 29, 32, 34 through 39, 41, 44, 52, 53, 55, 60
through 85, 88, 90, and 91.
If the RTCP XR feature is unavailable (not licensed or disabled), the R-factor VoIP
metrics are not provided in CDRs (CDR fields, Local R Factor and Remote R
Factor) generated by the device. Instead, these CDR fields are sent with the value
127, meaning that information is unavailable.
The following procedure describes how to customize SBC-related CDRs through the Web
interface. You can also configure it through ini file (SBCCDRFormat).
To customize SBC-related CDRs:
1.
Open the SBC CDR Format table (Configuration tab > System menu > Call Detail
Record > SBC CDR Format).
2.
Click Add; the following dialog box appears:
Figure 52-4: SBC CDR Format Table - Add Row Dialog Box
3.
Configure the CDR according to the parameters described in the table below.
4.
Click Add.