AudioCodes Mediant 3000 User Manual page 926

Media gateway & enterprise session border controller (e-sbc)
Hide thumbs Also See for Mediant 3000:
Table of Contents

Advertisement

Parameter
G729EV local MBS
[G729EVLocalMBS]
G729EV Maximum Bit Rate
[G729EVMaxBitRate]
G729EV receive MBS
[G729ECReceiveMBS]
User's Manual
Table 58-38: Coder Parameters
Defines the maximal bit rate (in kilobits per second - Kbps) that can
be used by the G.729EV coder for a specific channel. The
parameter is defined per channel and may vary between the
parties. The initial generation bit rate is the minimum between the
MaxBitRate and the MBS values.
[0] 8 KBPS (default)
[1] 12 KBPS
[2] 14 KBPS
[3] 16 KBPS
[4] 18 KBPS
[5] 20 KBPS
[6] 22 KBPS
[7] 24 KBPS
[8] 26 KBPS
[9] 28 KBPS
[10] 30 KBPS
[11] 32 KBPS
[15] Undefined
Defines the maximum generation bit rate for all participants in a
session using G.729EV coder. The parameter is defined per
session and is equal for all the parties. The initial generation bit rate
is the minimum between the MaxBitRate and the MBS values.
[0] 8 KBPS (default)
[1] 12 KBPS
[2] 14 KBPS
[3] 16 KBPS
[4] 18 KBPS
[5] 20 KBPS
[6] 22 KBPS
[7] 24 KBPS
[8] 26 KBPS
[9] 28 KBPS
[10] 30 KBPS
[11] 32 KBPS
[15] Undefined
Defines the value of the MBS field of the G.729EV frames to be
sent to the other party. The parameter reflects the maximum bit
rate, which the local G.729EV supports as a receiver.
[0] 8 KBPS (default)
[1] 12 KBPS
[2] 14 KBPS
[3] 16 KBPS
[4] 18 KBPS
[5] 20 KBPS
[6] 22 KBPS
[7] 24 KBPS
[8] 26 KBPS
926
Description
Document #: LTRT-89730
Mediant 3000

Advertisement

Table of Contents
loading

Table of Contents