Parameter
Sensitivity Level
[QOEColorRules_profile]
Green Yellow Threshold
[QOEColorRules_GreenYellowTh
reshold]
Green Yellow Hysteresis
[QOEColorRules_GreenYellowHy
steresis]
Yellow Red Threshold
[QOEColorRules_YellowRedThre
shold]
Yellow Red Hysteresis
[QOEColorRules_YellowRedHyst
eresis]
User's Manual
Defines the sensitivity level of the thresholds.
[0] User Defined = Need to define the thresholds in the
parameters described below.
[1] Low = Pre-configured low sensitivity threshold values.
Thus, reporting is done only if changes in parameters' values
are significant.
[2] Medium = (Default) Pre-configured medium sensitivity
threshold values.
[3] High = Pre-configured high sensitivity threshold values.
Thus, reporting is done for small fluctuations in parameter
values.
Defines the parameter threshold values between Green (good
quality) and Yellow (medium quality) states.
The valid threshold values are as follows:
MOS values are in multiples of 10. For example, to denote a
MOS of 3.2, the value 32 (i.e., 3.2*10) must be entered.
Delay values are in msec.
Packet Loss values are in percentage (%).
Jitter is in msec.
Echo measures the Residual Echo Return Loss (RERL) in dB.
Defines the fluctuation (change) from the value configured for the
Green-Yellow threshold. When the threshold is exceeded by this
hysteresis, the device sends a report to the SEM indicating this
change.
Note: If the monitored parameter crosses two thresholds at once
(e.g., from Green to Red), the device ignores the hysteresis value
and reports the call state change to the SEM.
Defines the parameter threshold values between Yellow (medium
quality) and Red (poor quality) states.
The valid threshold values are as follows:
MOS values are in multiples of 10. For example, to denote a
MOS of 3.2, the value 32 (i.e., 3.2*10) must be entered.
Delay values are in msec.
Packet Loss values are in percentage (%).
Jitter is in msec.
Echo measures the Residual Echo Return Loss (RERL) in dB.
Defines the fluctuation (change) from the value configured for the
Yellow-Red threshold. When the threshold is exceeded by this
hysteresis value, the device sends a report to the SEM indicating
this change.
Note: If the monitored parameter crosses two thresholds at once
(e.g., from Green to Red), the device ignores the hysteresis value
and reports the call state change to the SEM.
312
Description
Document #: LTRT-89730
Mediant 3000