Installing A Hot-Swap Dc Power Supply - Lenovo System x3650 M4 HD Installation And Service Manual

Table of Contents

Advertisement

Figure 49. Power information label
Step 10. If you are adding a power supply to the server, attach the redundant power information label that
comes with this option on the server cover near the power supplies.
Figure 50. Attaching the redundant power information label

Installing a hot-swap dc power supply

Observe the following precautions when you install a hot-swap dc power supply.
The following notes describe the type of power supply that the server supports and other information that
you must consider when you install a power supply:
• Before you install an additional power supply or replace a power supply with one of a different wattage,
you may use the Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to http://www.ibm.com/systems/ bladecenter/resources/
powerconfig.html.
• The server comes with one hot-swap 12-volt output power supply that connects to power supply bay 1.
The input voltage is -48 V dc or -60 V dc auto-sensing.
• Before you install a dc power supply in the server, you must remove all ac power supplies. Do not use
both ac and dc power supplies in the same server. Install up to two dc power supplies or up to two ac
power supplies, but not a combination.
64
Lenovo System x3650 M4 HD Installation and Service Guide
XXXW ~ AC
1
xxx-xxx/
xxx-xxxV~
x,x/x,x A
xx/xx Hz
Power supplies
XXXW ~ AC
2
xxx-xxx/
xxx-xxxV~
x,x/x,x A
xx/xx Hz

Advertisement

Table of Contents
loading

Table of Contents