a.
Insert the drive into the drive bay with the label side of the drive facing the right side of the
server.
1.8-inch
hot-swap
hard disk drive
Figure 136. 1.8-inch hot-swap solid state drives installation
b.
Push the drive tray into the drive bay and rotate the drive tray handle to the closed position
and ensure that the latch is in the locked position.
c.
Reinstall the filler panel.
Step 6.
Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If
the yellow hard disk drive status LED of a drive is lit continuously, that drive is faulty and must be
replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed.
Note: If the server is configured for RAID operation using a ServeRAID adapter, you might have
to reconfigure your disk arrays after you install hard disk drives. See the ServeRAID adapter
documentation for additional information about RAID operation and complete instructions for
using the ServeRAID adapter.
Step 7.
If you are installing additional hot-swap hard disk drives, do so now.
Step 8.
Turn on the peripheral devices and the server.
Drive IDs
The drive ID that is assigned to each drive is printed on the front or rear of the server. The following
illustrations show the locations of the IDs of the drives. The ID numbers and the drive bay numbers are
the same.
2.5-inch hot-swap hard disk drive IDs
The hot-swap-drive ID that is assigned to each drive is printed on the front or rear of the server.
The following illustration shows the location of the IDs of the hard disk drives. The ID numbers and the
drive bay numbers are the same.
Filler
.
Chapter 6
Removing and replacing components
213