Lenovo System x3650 M4 HD Installation And Service Manual page 509

Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk
drive backplane (n = hard disk drive number)
• 806f010d-0411ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 17)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0411ffff or 0x806f010d0411ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk
drive backplane (n = hard disk drive number)
• 806f010d-0412ffff : The Drive [StorageVolumeElementName] has been disabled due to a detected
fault. (Drive 18)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d0412ffff or 0x806f010d0412ffff
Appendix A. Integrated management module II (IMM2) error messages
497

Advertisement

Table of Contents
loading

Table of Contents