Lenovo System x3650 M4 HD Installation And Service Manual page 702

Table of Contents

Advertisement

1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
806f0a0c-2006ffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2006ffff or 0x806f0a0c2006ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications (see
Features and specifications for more information).
806f0a0c-2007ffff : An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2007ffff or 0x806f0a0c2007ffff
Severity
Error
Serviceable
690
Lenovo System x3650 M4 HD Installation and Service Guide

Advertisement

Table of Contents
loading