Lenovo System x3650 M4 HD Installation And Service Manual page 587

Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0062
User Response
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0507-0302ffff : [ProcessorElementName] has a Configuration Mismatch. (CPU 2)
This message is for the use case when an implementation has detected a Processor Configuration
Mismatch has occurred.
May also be shown as 806f05070302ffff or 0x806f05070302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
User Response
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0507-2584ffff : [ProcessorElementName] has a Configuration Mismatch. (All CPUs)
Appendix A. Integrated management module II (IMM2) error messages
575