Lenovo System x3650 M4 HD Installation And Service Manual page 418

Table of Contents

Advertisement

80010b01-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper
non-recoverable) has asserted. (DIMM AB VR Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011403ffff or 0x80010b011403ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node
cover is installed and completely closed.
2. Make sure the fans are operating, and there are no obstructions to the airflow.
3. Reduce the Ambient temperature. The system must be operating within the specifications.(see
Features and specifications for more information)
80010b01-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper
non-recoverable) has asserted. (DIMM CD VR Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011404ffff or 0x80010b011404ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
406