Lenovo System x3650 M4 HD Installation And Service Manual page 626

Table of Contents

Advertisement

2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-041effff : Array [ComputerSystemElementName] is in critical condition. (Drive 30)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d041effff or 0x806f050d041effff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Check backplane cable connection.
5. Replace the RAID adapter.
6. Replace the hard disk drive that is indicated by a lit status LED.
• 806f050d-041fffff : Array [ComputerSystemElementName] is in critical condition. (Drive 31)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d041fffff or 0x806f050d041fffff
Severity
Error
Serviceable
Yes
614
Lenovo System x3650 M4 HD Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents