Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Description
Error code
217-000-000
Passed the storage drive self test.
217-900-xxx
Failed the storage drive self test.
217-800-xxx
The storage drive self test was terminated by
the user.

Tape alert flags

Use this information to diagnose and resolve tape alert flags for the blade server.
Tape alert flags are numbered 1 through 64 and indicate a specific media-changer error condition. Each tape
alert is returned as an individual log parameter, and its state is indicated in bit 0 of the 1-byte Parameter
Value field of the log parameter. When this bit is set to 1, the alert is active.
Each tape alert flag has one of the following severity levels:
C - Critical
W - Warning
I - Information
Different tape drives support some or all of the following flags in the tape alert log:
Flag 2: Library Hardware B (W) This flag is set when an unrecoverable mechanical error occurs.
Flag 4: Library Hardware D (C) This flag is set when the tape drive fails the power-on self-test or a
mechanical error occurs that requires a power cycle to recover. This flag is internally cleared when the
drive is powered-off.
Action
N/A
1. Make sure that the storage drive is securely
connected in the storage drive connector, then;
reseat the storage drive.
2. Rerun the test.
3. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test. The BIOS firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support Web site at http://
www.ibm.com/support/docview.wss?uid=
psg1MIGR-63017.
4. Rerun the test.
5. If the component failure remains, refer to
Chapter 4 "Removing and replacing blade
server components" on page 37 to replace the
failed component.