Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 200

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0813
806f0813-2582ffff
184
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
Group 2, (PCI
express bus 1-2,
Expansion Module
2-0)
• (All PCI Error)
bus
uncorrectable
error,
• (One of PCI
Error) bus
uncorrectable
error, or
• (PCIs) bus
uncorrectable
error
Action
server in a
BladeCenter unit" on
page 39).
3. Update the device
drivers for any
expansion cards that
are installed into the
blade server.
4. Reseat the expansion
card (see "Removing
an I/O expansion
card" on page 50 and
"Installing an I/O
expansion card" on
page 53).
5. Replace the
expansion card (see
"Removing an I/O
expansion card" on
page 50 and
"Installing an I/O
expansion card" on
page 53).
1. If this is a newly
installed option,
ensure the matching
Processors are
installed in the correct
Processor sockets.
2. Verify that the
Processor is a valid
option and is listed as
a Serverproven
device for the system.
3. If a non-supported
processor is
identified, remove the
Processor or replace
with a supported
Processor.
4. Check IBM support
website for a firmware
update required for
the Processor and
install the update.
5. (Trained technician
only)