Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 159

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0107
806f0107-2584ffff
Type
Error Message
Error
Group 4,
processor X (All
CPUs) thermal trip
[Note: X=1,2]
Action
heat sink" on page
65.
1. Make sure that the
room temperature is
within the operating
specifications (see
"Features and
specifications" on
page 2).
2. Make sure that none
of the air vents on the
BladeCenter unit and
on the blade server
are blocked.
3. Make sure that all of
the fans on the
BladeCenter unit are
running.
4. Make sure that each
bay of the
BladeCenter unit has
either a device or a
filler installed.
5. Make sure that the
blade server is not
missing any heat
sinks, DIMMs, heat-
sink fillers, or DIMM
fillers (see Chapter 3
"Parts listing" on
page 29).
6. Clear the CMOS data
by removing the
system battery for 30
seconds (see
"Removing the
battery" on page 41
and "Installing the
battery" on page 42).
7. Make sure that the
heat sink is properly
attached to the
microprocessor (see
"Installing a
microprocessor and
heat sink" on page
65).
.
143
Chapter 5
Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents