• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f050c
806f050c-2001ffff
806f050c-2002ffff
806f050c-2003ffff
806f050c-2004ffff
806f050c-2005ffff
806f050c-2006ffff
806f050c-2007ffff
806f050c-2008ffff
806f050c-2009ffff
806f050c-200affff
806f050c-200bffff
806f050c-200cffff
806f050c-200dffff
806f050c-200effff
806f050c-200fffff
806f050c-2010ffff
168
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
Memory device X
(DIMM X)
correctable ECC
memory error
logging limit
reached [Note X =
1-16]
Action
"Installing a
microprocessor
and heat sink" on
page 65).
b. Inspect Processor
socket and
replace the
system-board
assembly (see
"Removing the
system-board
assembly" on
page 71 and
"Installing the
system-board
assembly" on
page 71) first if
socket is
damaged.
1. Refer to TIP H21455
for minimum code
level.
2. Check the IBM
support website for
an applicable retain
tip or firmware update
that applies to this
memory error.
3. Swap the affected
memory modules (as
indicated by the error
LEDs on the system
board or the event
logs) to a different
memory channel or
microprocessor (see
"Installing a memory
module" on page 47
for memory
population
sequence).
4. If the error occurs
again on the same
memory module,
replace the affected
memory module.
5. (Trained technician
only) If the problem