Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 192

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0513
806f0513-3101ffff
806f0513-3102ffff
0x806f0528
806f0528-2101ffff
176
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
PCI express bus
X, (PCI Slot X) PCI
system error
[Note: X = 1,2]
Warning
System mgmt
software, (IMM2
FW Failover) FRU
failure
Action
and "Installing a
microprocessor and
heat sink" on page
65).
1. Check the operating
system event log and
the system event log
as it may contain
additional information
(see "Event logs" on
page 79).
2. Reseat the blade
server in the
BladeCenter (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
server in a
BladeCenter unit" on
page 39).
3. Update the device
drivers for any
expansion cards that
are installed into the
blade server.
4. Reseat the expansion
card (see "Removing
an I/O expansion
card" on page 50 and
"Installing an I/O
expansion card" on
page 53).
5. Replace the
expansion card (see
"Removing an I/O
expansion card" on
page 50 and
"Installing an I/O
expansion card" on
page 53).
1. Refresh or update the
IMM firmware.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents