Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 178

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0413
806f0413-2582ffff
162
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
Group 2, (PCI
express bus 1-2,
Expansion Module
2-0)
• (All PCI Error)
PCI parity error,
• (One of PCI
Error) PCI parity
error, or,
• (PCIs) PCI
parity error
Action
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. If this blade and/or
any attached cables
were recently
installed, moved,
serviced, or
upgraded, perform
the following steps:
a. Reseat the
adapter and any
attached cables.
b. Reload the device
driver.
c. If the device is not
recognized, re-
configure slot to
Gen1 or Gen2.
d. You can configure
Gen1/Gen2
settings in F1
Setup.
1) Go to System
Settings →
Devices and
I/O Ports →
PCIe Gen1/
Gen2/Gen3
Speed
Selection , or
the ASU
Utility.
2. Check IBM support
website for an
applicable device
driver, firmware
update, pdsg revision
or other information
that applies to this
error.
3. Load new device
driver and any

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents