• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0813
806f0813-3101ffff
806f0813-3102ffff
0x806f0A07
806f0A07-2584ffff
0x806f0a0c
806f0a0c-2001ffff
806f0a0c-2002ffff
806f0a0c-2003ffff
806f0a0c-2004ffff
806f0a0c-2005ffff
806f0a0c-2006ffff
806f0a0c-2007ffff
806f0a0c-2008ffff
Type
Error Message
Error
PCI express bus
X, (PCI Slot X) bus
uncorrectable
error [Note: X =
1,2]
Information
Blade CPU Auto
Throttle
Error
Memory device X,
(DIMM X) memory
in critical over-
temperature state
Throttled X [Note
X=1-16]
Action
1. Check the operating
system event log and
the system event log
as it may contain
additional information
(see "Event logs" on
page 79).
2. Reseat the blade
server in the
BladeCenter (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
server in a
BladeCenter unit" on
page 39).
3. Update the device
drivers for any
expansion cards that
are installed into the
blade server.
4. Reseat the expansion
card (see "Removing
an I/O expansion
card" on page 50 and
"Installing an I/O
expansion card" on
page 53).
5. Replace the
expansion card (see
"Removing an I/O
expansion card" on
page 50 and
"Installing an I/O
expansion card" on
page 53).
Information only.
1. Make sure that the
room temperature is
within the operating
specifications (see
"Features and
specifications" on
page 2).
.
187