• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0813
806f0813-2581ffff
Type
Error Message
Error
Group 1, (memory
device 1-16)
(DIMMs) bus
uncorrectable
error
Action
expansion card" on
page 53).
9. Replace the
expansion unit (see
"Removing an
optional expansion
unit" on page 58 and
"Installing an optional
expansion unit" on
page 59).
10. If the system contains
multiple
microprocessors,
swap the
microprocessors (see
"Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
11. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. Check the operating
system event log and
the system event log
as it may contain
additional information
(see "Event logs" on
page 79).
2. Reseat the blade
server in the
BladeCenter (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
.
183
Chapter 5
Diagnostics