Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 224

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Lit light path
diagnostics LED
Description
Microprocessor
The microprocessor has failed or overheated,
error
or the start microprocessor is missing.
NMI (NMI error)
The system board has failed.
SAS storage drive
A storage drive has failed.
error
208
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Action
1. Check the Integrated Management Module
II (IMM2) log for more information. See
"Viewing event logs through the Setup
utility" on page 79.
2. If the log shows that a microprocessor is
disabled or that a microprocessor error
has occurred, perform one of the following
actions:
a. (Trained technician only) Reseat the
microprocessor that is indicated by the
lit LED. See "Removing a
microprocessor and heat sink" on page
61 and "Installing a microprocessor
and heat sink" on page 65.
b. (Trained technician only) Replace the
microprocessor that is indicated by the
lit LED. See "Removing a
microprocessor and heat sink" on page
61 and "Installing a microprocessor
and heat sink" on page 65.
1. Replace the blade server cover, reinsert
the blade server in the BladeCenter unit,
and then restart the blade server. Check
the BMC log for information about the
error. See "Using the Setup utility" on page
11.
2. (Trained technician only) Replace the
system-board assembly. See "Removing
the system-board assembly" on page 71
and "Installing the system-board
assembly" on page 71.
Run the SAS Attached Disk diagnostic test. If
the drives passes diagnostics but continues to
have a problem, replace the storage drive with
a new one. See "IBM Dynamic System Analysis
Preboot diagnostic program" on page 209.