Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 127

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80010900
80010902-0701ffff
0x80010900
80010902-0701ffff
Type
Error Message
Error
System board
(SysBrd 3.3V)
voltage over
critical threshold.
Reading: X,
Threshold: Y
Error
System board
(SysBrd 5V)
voltage over
critical threshold.
Reading: X,
Threshold: Y
Action
BladeCenter unit are
running.
4. Check the error logs
about the
temperature and the
fan (see "POST/UEFI
diagnostic codes" on
page 81).
Replace the blade (see
"Removing the system-
board assembly" on page
71 and "Installing the
system-board assembly"
on page 71).
1. Remove all expansion
cards from the blade
server (see
"Removing an I/O
expansion card" on
page 50).
2. Remove all storage
drives from the blade
server (see
"Removing a hot-
swap storage drive"
on page 44).
3. If the error continues,
replace the system-
board assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
.
111
Chapter 5
Diagnostics