• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0108
806f0108-0701ffff
Type
Error Message
Error
System board,
Power Module
(VRD Fault) failure
Action
heat sink" on page
65).
7. (Trained technician
only) If the error still
occurs, replace the
microprocessor that
controls the failing
memory module. See
"Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65.
1. Make sure that the
latest firmware is
being used (see
"Updating firmware
and device drivers"
on page 23).
2. Reseat the blade
server in the
BladeCenter (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
server in a
BladeCenter unit" on
page 39).
3. Reset the UEFI
firmware settings to
default values using
the Setup utility (see
"Using the Setup
utility" on page 11).
4. (Trained technician
only) Replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
.
145
Chapter 5
Diagnostics