Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 137

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070200
8007020f-2582ffff
Type
Error Message
Error
Group 2, (PCI
express bus 1-2,
Expansion Module
2-1) firmware
progress (No I/O
Resources) critical
Action
system battery for 30
seconds (see
"Removing the
battery" on page 41
and "Installing the
battery" on page 42).
9. Make sure that the
heat sink is properly
attached to the
microprocessor (see
"Installing a
microprocessor and
heat sink" on page
65).
Complete the following
steps for PCI I/O resource
error issue resolution:
1. Understand the I/O
resource
requirements in a
basic system.
2. Identify the I/O
resource
requirements for
desired add-in
adapters. For
examples, PCI-X or
PCIe adapters.
3. Disable on-board
devices that you can
do without and that
request I/O.
4. In F1 setup, select the
System Settings →
Device and I/O
menu.
5. Remove adapters or
disable slots until the
I/O resource is less
than 64 KB.
.
121
Chapter 5
Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents