Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 141

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070200
80070217-3101ffff
Type
Error Message
Error
PCI express bus 1,
Expansion Card
(CFFh Fault)
critical
Action
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
Complete the following
steps:
1. Remove any recently
installed CFFh Card.
2. Power on the node. If
the node can be
powered-on
successfully,
complete the steps
below:
a. Check the
ServerProven
website to make
sure that the
recently installed
components are
compatible with
the compute
node.
b. Inspect the
previously
installed
components for
physical damage.
3. If the node cannot be
powered-on
successfully, or if this
is not the first
occurrence of the
problem, you need to
replace the CFFh
Card.
.
125