Imm Error Messages - Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Diagnostic
Message
code
I.3868000
[I.3868000] BOFM:
System reset performed
to reset adapters.
W.3868001
[W.3868001] BOFM:
Reset loop avoided -
Multiple resets not
allowed.
W.3868002
[W.3868002] BOFM:
Error communicating
with the IMM - BOFM
may not be deployed
correctly.
I.3868003
[I.3868003] BOFM:
Configuration too large
for compatibility mode.
W.3938002
[W.3938002] A boot
configuration error has
been detected.

IMM error messages

Use this information to resolve IMM error messages.
The following table lists IMM error messages and suggested actions to correct the detected problems.
Deassertive events not listed in this table are informational only.
Notes:
• Error Code = IMM events displayed by AMM (for example, Service Advisor, AMM web interface)
• Event ID = IMM events displayed by DSA diagnostic program (for example, in the Chassis Event Log
section)
Description
BOFM: System reset
performed to reset
adapters.
BOFM: Reset loop
avoided - Multiple resets
not allowed.
BOFM: Error
communicating with the
IMM - BOFM may not
be deployed correctly.
BOFM: Configuration
too large for
compatibility mode.
Boot Configuration
Error.
Action
No action; information only.
1. Check the IBM support website for an
applicable retain tip or firmware update
(including adapters) that applies to this
memory error.
2. Contact your IBM service representative for
support.
1. Check the IBM support website for an
applicable retain tip or firmware update
(including adapters) that applies to this
memory error.
2. Contact your IBM service representative for
support.
No action; information only.
1. Run the Setup utility (see "Using the Setup
utility" on page 11), select Load Default
Settings, and save the settings.
2. Recover the server firmware (see
"Recovering from a UEFI update failure" on
page 254).
Chapter 5
.
105
Diagnostics