Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 142

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070200
80070217-3102ffff
0x80070200
80070219-0701ffff
126
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
PCI express bus 2,
Expansion Card
(CIOv Fault) critical
Error
System board,
chip set (SysBrd
Fault) critical
Action
Complete the following
steps:
1. Remove any recently
installed CIOv Card.
2. Power on the node. If
the node can be
powered-on
successfully,
complete the steps
below:
a. Check the
ServerProven
website to make
sure that the
recently installed
components are
compatible with
the compute
node.
b. Inspect the
previously
installed
components for
physical damage.
3. If the node cannot be
powered-on
successfully, or if this
is not the first
occurrence of the
problem, you need to
replace the CIOv
Card.
1. Make sure that the
latest firmware is
being used (see
"Updating firmware
and device drivers"
on page 23).
2. Reseat the blade
server in the
BladeCenter (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
server in a