Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 171

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f020d
806f020d-0401ffff
806f020d-0402ffff
0x806f0212
806f0212-2584ffff
Type
Error Message
Warning
Hard drive X (Drive
X) predictive
failure [Note X=
0,1]
Error
Group 4,
processor X (CPU
Fault Reboot)
system hardware
failure [Note X=
1,2]
Action
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
5. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
Replace the storage drive
(see "Removing a hot-
swap storage drive" on
page 44 and "Installing a
hot-swap storage drive"
on page 44).
1. Verify that you have
the latest system
firmware (see
"Updating firmware
and device drivers"
on page 23).
2. Clear the CMOS data
by removing the
system battery for 30
seconds (see
"Removing the
battery" on page 41
and "Installing the
battery" on page 42).
3. (Trained technician
only) If the error still
occurs, replace
microprocessor X
(see "Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
.
155
Chapter 5
Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents