Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 143

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070300
80070301-0301ffff
80070301-0302ffff
Type
Error Message
Error
Processor X,
temperature (CPU
X OverTemp) non-
recoverable [Note:
X=1, 2]
Action
BladeCenter unit" on
page 39).
3. Reset the UEFI
firmware settings to
default values using
the Setup utility (see
"Using the Setup
utility" on page 11).
4. Clear the CMOS data
by removing the
system battery for 30
seconds (see
"Removing the
battery" on page 41
and "Installing the
battery" on page 42).
5. (Trained technician
only) Replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. Check the system
event log for
additional
temperature and fan
information (see
"Event logs" on page
79).
2. Make sure that the
room temperature is
within the operating
specifications (see
"Features and
specifications" on
page 2).
3. Make sure that none
of the air vents on the
BladeCenter unit and
on the blade server
are blocked.
4. Make sure that all of
the fans on the
.
127
Chapter 5
Diagnostics

Advertisement