Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 128

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80010900
80010902-0701ffff
0x80010b00
80010b01-1001ffff
80010b01-1002ffff
80010b01-1003ffff
80010b01-1004ffff
112
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
System board
(SysBrd 12V)
voltage over
critical threshold.
Reading: X,
Threshold: Y
Error
Expansion Module
0 or 2, (GPU_X
TMP) temperature
over non-
recoverable
threshold.
Reading: 6.10;
Threshold: 7.00
[Note: X=1-4]
Action
1. If the over voltage
problem is occurring
on all blade servers,
look for other events
in the log related to
power and resolve
those events.
2. View the event log
provided by the
advanced
management module
for your BladeCenter
unit and resolve any
power related errors
that might be
displayed.
3. If other modules or
blades are logging the
same issue then
check the power
supply for the
BladeCenter unit.
4. If the error continues,
replace the system-
board assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. Check the IBM
support website for
an applicable retain
tip or firmware update
that applies to this
temperature error.
2. Make sure that the
room temperature is
within the operating
specifications (see
"Features and
specifications" on
page 2).
3. Make sure that none
of the air vents on the
BladeCenter unit and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents