Field Service Ver.2.0 Jan. 2007
[5]
[7]
2.1.3
Cleaning of the Pick-up Roller, Feed Roller and Separation Roller
A. Periodic cleaning parts/cycle
• Pick-up Roller: Every 250,000 prints (Actual replacement cycle: Every 50,000 faces)
• Feed Roller: Every 250,000 prints (Actual replacement cycle: Every 50,000 faces)
• Separation Roller: Every 250,000 prints (Actual replacement cycle: Every 50,000 faces)
B. Procedure
[1]
Confidential – for internal use only, do not distribute
3. Remove the Separation Roller Assy [4].
NOTE
[4]
• Use care not to lose the spring at the
bottom side of the Separation Roller
Assy.
16eaf2c008na
4. While opening up the holder [5], remove
the Separation Roller Shaft [6].
NOTE
• Opening the holder too much can
break the holder.
[6]
16eaf2c009na
5. Remove the Separation Roller [7] from
the Separation Roller Shaft.
16eaf2c010na
1. Open the Open/Close Cover [1].
16eaf2c011na
2. PERIODIC CHECK
7