Filter Motor Relay; Check Valve - Henny Penny LVE-202 Technical Manual

Split vat & full vat open fryers – electric
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

7-18. FILTER MOTOR RELAY

7-19. CHECK VALVE

Apply Primer Here
Apply Primer Here
Oct. 2010
This component is located behind the left control panel and
regulates voltage to the filter motor. Part No. is ME90-008.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Support control panel bottom with 1 hand, loosen retaining
screw at panel top, slide panel down slightly to clear screw,
push panel back up, then swing panel top out and down.
2. Label and remove wires from relay.
3. Using a 5/16" socket, remove nuts securing the relay and
remove relay from fryer.
4. Install new relay in reverse order.
5. Support control panel bottom with 1 hand, swing panel top
up about 90 degrees, slide panel down slightly to clear
screw, push panel up to engage screw, and tighten screw.
A check valve is installed in the fill line to each vat to keep oil
from flowing out of the vat.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Disassemble flexible oil lines and fittings from valve as
necessary.
2. Apply Loctite Primer (Henny Penny part no. MS01-572) to
internal threads of both the inlet and outlet of valve.
3. Reassemble fittings to check valve and install valve and oil
lines.
7-23
Model LVE-202, 203, 204

Hide quick links: