Deep Clean Mode - Henny Penny LVE-202 Technical Manual

Split vat & full vat open fryers – electric
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

3-2. AIF CLOCK
(Continued)

3-3. DEEP CLEAN MODE

Oct. 2010
In 12-hour clock mode, there are three items on each line: the start
time "XX:XX", the A or P (am/pm) setting, and the "XX" duration.
Use the and buttons to set these items, which flashes when
the item is selected.
To set a new start time setting, use the product buttons,
Press the
button to step over to the AM/PM setting. The A or P
can be toggled by pressing the '0' product button.
Press the
button again to step over to the duration value (in
minutes). Enter a new value using the product buttons,
In 24-hour clock mode, there are only two items on each line: the
time (XX:XX) and the duration (XX). Again, the
buttons step you between these items.
Press the right-side X button to exit out of AIF Clock programming
mode.
This procedure allows a thorough cleaning of the vat by remov-
ing caramelized oil from vat. See Section 4-3 in the Operator's
Manual for complete set of instructions.
3-4
Model LVE-202, 203, 204
to enter the new value.
and

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lve-204Lve-203

Table of Contents