3-13.
FILTER PUMP
MOTOR
PROTECTOR-
MANUAL RESET
3-12.
CLEANING THE
FRYPOT
July 2003
The filter pump motor is equipped with a manual reset button, located
on the rear of the motor, in case the motor overheats. Wait approxi-
mately 5 minutes before attempting to reset this protective device to
allow motor to cool. Remove the access panel on the left side panel of
the unit to reset the button. It takes some effort to reset, and a screw-
driver can be used to help reset the button.
To prevent burns caused by splashing shortening,
turn the unit's main power switch to the OFF
position before resetting the filter pump motor's
manual reset protection device.
After the initial installation of the fryer, as well as before every
change of shortening, the frypot should be thoroughly cleaned as
follows:
1.
Turn the COOK/PUMP switch to OFF, and unplug unit from
wall receptacle.
Moving the fryer or filter drain pan while contain-
ing hot shortening is not recommended. Hot short-
ening can splash out and severe burns could result.
The filter drain pan must be as far back under fryer
as it will go, and the cover in place. Be sure the hole
in the cover lines up with the drain before opening
the drain. Failure to follow these instructions causes
splashing of shortening and could result in personal
2.
If hot shortening is present in the frypot, it must be drained
by slowly pulling the drain handle out towards you.
3.
Close the drain valve and discard the shortening.
4.
Remove the racks and carrier from lid, and tilt lid back, so
that the lid won't interfere with cleaning.
33