Chapter 8 Troubleshooting; Filter Pump Motor Protector - Manual Reset; Troubleshooting Guide; Table 8-1 Troubleshooting Guide - Henny Penny KFC Velocity Series Operation Manual

Hide thumbs Also See for KFC Velocity Series:
Table of Contents

Advertisement

C C h h a a p p t t e e r r 8 8 T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g
8 8 . . 1 1 F F i i l l t t e e r r P P u u m m p p M M o o t t o o r r P P r r o o t t e e c c t t o o r r - - M M a a n n u u a a l l R R e e s s e e t t
T T o o p p r r e e v v e e n n t t b b u u r r n n s s c c a a u u s s e e d d b b y y s s p p l l a a s s h h i i n n g g o o i i l l , , t t u u r r n n t t h h e e u u n n i i t t ' ' s s
m m a a i i n n p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f p p o o s s i i t t i i o o n n b b e e f f o o r r e e r r e e s s e e t t t t i i n n g g t t h h e e f f i i l l t t e e r r
p p u u m m p p m m o o t t o o r r ' ' s s m m a a n n u u a a l l r r e e s s e e t t p p r r o o t t e e c c t t i i o o n n d d e e v v i i c c e e . .
The filter pump motor is equipped with a manual reset button located on the rear of
the motor. Wait about 5 minutes before attempting to reset this protective device to
allow motor to cool. Remove the condensation pan to reveal the reset button. It takes
some effort to reset, and a screwdriver can be used to help reset the button.
8 8 . . 2 2 T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g G G u u i i d d e e
More detailed troubleshooting information is available in the
NOTICE
Technical Manual, available at or contact Technical Support at
:
1-800-417-8405 or 1-937-456-8405.
Problem
Power switch is on
Open circuit.
but the fryer is com-
pletely inoperative.
Oil not heating.
High temperature limit
tripped.
Foaming or boiling
Some customers choose not
over.
to use oil stabilizers which
can cause foaming and boil-
over.
See boil-over chart on fryer
and Boil-Over Prevention
section of Operator's Manual.
T T a a b b l l e e 8 8 - - 1 1 T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g G G u u i i d d e e
Cause
Correction
Fryer plugged in.
Check breaker or fuse at wall.
Check circuit breakers between
control panel and ATO tank.
Reset high temperature limit. Refer
to 3.1 Operating Components in the
Operator's Manual.
Product with excessive ice crystals
should be dipped once quickly then
removed from the fryer to allow ice
crystals to melt and excessive water
to evaporate. Then place the product
back into the fryer and cook
normally.
Refer to 2.7 Boil-Over Prevention in
the Operator's Manual.