7-17. TRANSFORMERS
(Continued)
Control Transformer
AIF Transformer

7-18. FILTER MOTOR RELAY

July 2010
Checkout (Continued):
11. If control panel still does not display, replace panel with a
known good control panel. If problem follows control
panel, replace panel.
Replacement:
1. Disconnect electrical power and using a 5/16" socket,
remove nuts securing transformer and remove transformer.
2. Replace transformer in reverse order.
This component is located behind the left control panel and
regulates voltage to the filter motor.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Pull-down the left control panel.
2. Label and remove wires from relay.
3. Using a 5/16" socket, remove the nuts securing relay and
remove relay from fryer.
4. Install new relay in reverse order.