7-14. FILTER PUMP &
MOTOR
Oct. 2010
The 2 most common causes for a fryer not to pump oil are that
the pump is clogged, or the thermal overload switch has been
tripped on the motor. The pump and motor is located behind
the middle door above the drain pan.
To remove debris from pump:
1. Loosen four Allen head screws on end of pump and
remove cover. (Removing the bottom rear panel may help
in accessing the set screws.)
2. The inside is now exposed leaving a rotor and five teflon
rollers. Clean the rotor and rollers.
3. To reassemble, place rotor on drive shaft, and place roller
into rotor.
A small amount of grease might be needed to hold the
bottom roller into place until cover plate is put on. Make
sure O-ring is in proper position on plate.
There is an indicator on the side of the two halves of the
pump, this mark must be together
To reset the thermal overload switch:
1. Open middle door, locate pump and motor above drain pan
and if the motor is hot, allow it to cool for about 5 minutes.
2. Since it takes some effort to reset the switch, use a tool,
such as a Phillip's-head screwdriver, to press against the
reset button until an audible "click" is heard.