Henny Penny LVE-202 Technical Manual page 35

Split vat & full vat open fryers – electric
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

5-5. TECH MODE (Continued)
Oct. 2010
T-20 - PUMPS & VALVES (Continued)
Press
to open and close the RTI discard valve (display shows
"DISCARDo" when open)
Press to open and close the RTI JIB fill valve (display shows
"JIBFILLo" when open)
Press
and "SEL-VALV" "AT HOME" shows in the dis-
plays.
Press
button and "REV, CNT" " HOM, POS" followed by
actual data values such as "3.19R 10P" "14.4° 15.2°". One
revolution of the valve took 3.19 seconds, counted 10 ports
during the revolution, the dwell angle of the home switch was
14.4°, and the dwell angle of the position switch was 15.2°.
Press
button and "CALIBRAT" "AT HOME" show in the
displays. Press √ button to request a calibration, data values as
above will appear in the displays.
Press
button and "NEXT POS" "AT HOME" show in the
displays. Press left √ button and valve moves to next port position.
Press
button and "CONT RUN" "AT HOME" show in the
displays. Press left √ button and valve will run continuously until
you press the STOP button.
Press button and "RAW√ MTR_" "D√ Hx P*" shows in the
displays. The √ indicates a signal was constanly "ON", the "_"
means a signal was constantly "OFF", and the "X means the signal
was both "ON" and "OFF".
Press
button and "PUMP FP_" and "JP_ NP_" shows in the
displays. (Driven by the AIF board)
Press to turn off and on the filter pump (display shows "FP*"
when on)
Press
to turn off and on the JIB pump (display shows "JP*"
when on)
Press
to turn off and on the RTI new oil pump (display
shows "NP*" when on)
Press
button and "LIGHTS" and "FLT_ JLO_" shows in
the displays. (Driven by the AIF board)
5-11
Model LVE-202, 203, 204

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lve-204Lve-203

Table of Contents