Henny Penny LVE-202 Technical Manual page 28

Split vat & full vat open fryers – electric
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

5-2. SPECIAL PROGRAMMING
(Continued)
Oct. 2010
2nd Language (SP-3)
6. Press button and "SP-3 2ND LANGUAGE" scrolls in
left display. Use
FRANCAIS; CAN FREN; ESPANOL; PORTUG;
DEUTSHE; SVENSKA; РУССКИИ or -NONE-.
By setting a second language in the controls, 2 languages
can now be easlily chosen by pressing
during normal operation.
One language shows in left display and a second language
shows in the right display. Pressing the √ button selects the
language in the displays.
2nd Volume (SP-4)
7. Press button; "SP-4" and "2ND VOLUME" flash on
the left display. Press the
the desired 2nd volume.
By setting a 2nd volume in controls, 2 volumes can now
be easlily chosen by pressing
normal operation.
One volume setting shows in the left display (NONE to 10;
10 being the loudest) and the second volume shows in the
right display. To select the volume, press the √ button
under the desired volume .
Quick Configuration (SP-5)
8. Press button and "SP-5 QUICK CONFIG" shows in
display. Use the
selection in the controls to: CHKN+FSH; FF/HBR;CHKN
or EMPTY.
Polish Duration (SP-6)
9. Press button and "SP-6 POLISH" shows in left
display. Use product buttons
to change polish time, from 5 minutes to a maximum of 10
minutes.
Drain Valve (SP-7)
10. Press button and "SP-7 DRAIN VALVE" scrolls in
left display. Use the
display to show "NORMAL" or "MANUAL".
NORMAL means the drain valves are controlled electronic-
ally and MANUAL means the drain valves must be opened
by hand.
5-4
Model LVE-202, 203, 204
and
buttons to set to: ENGLISH;
button twice
or
buttons to select
button 3 times during
and
buttons to change the menu
and
buttons to change right

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lve-204Lve-203

Table of Contents