    Model LVE-202, 203, 204 TABLE OF CONTENTS Section Page Section 1. TROUBLESHOOTING ....................1-1 Introduction ....................1-1 Safety ......................1-1 Troubleshooting ....................1-2 Error Code Table .................... 1-7 Section 2. INFO, FILTER & TEMP BUTTON STATS ............... 2-1 INFO Button Stats ..................2-1 FILTER Button Stats ..................
  • Page 4 Recommended Spare Parts Lists for Distributors .......... 8-1 Appendix A A-1 Wiring Diagrams & Scematics ............... A-1 Wiring Diagrams .................... A-2 Control Panel Label ..................A-22 RTI/Henny Penny System Operation ............. A-23 Selector Valve Plumbing Diagrams ..............A-24 May 2016...
  • Page 5: Section 1. Troubleshooting

    Model LVE-202, 203, 204 SECTION 1. TROUBLESHOOTING 1-1. INTRODUCTION This section provides troubleshooting information in the form of an easy to read table. If a problem occurs during the first operation of a new fryer, recheck the installation per the Installation Section of the Operator’s manual. Before troubleshooting, always recheck the operation pro- cedures per Section 3 of the Operator’s manual.
  • Page 6: Troubleshooting

    Model LVE-202, 203, 204 1-3. TROUBLESHOOTING To isolate a malfunction, proceed as follows: 1. Clearly define the problem (or symptom) and when it occurs. Locate the problem in the Troubleshooting table. Review all possible causes. Then, one-at-a-time work through the list of corrections until the problem is solved.
  • Page 7 Model LVE-202, 203, 204 Problem Cause Correction POWER SECTION • • With power switch in Open circuit Check to see that unit is plugged in ON position, the fryer • is completely inoperative Check the breaker or fuse at supply box •...
  • Page 8 Model LVE-202, 203, 204 Problem Cause Correction HEATING OF SHORTENING SECTION (Continued) Oil will not heat • • Drain valve open Close drain valve (Continued) • • Possible faulty temperature probe Replace temperature probe • • Faulty contactor Check contactor per maintenance section on contactors •...
  • Page 9 Model LVE-202, 203, 204 Problem Cause Correction OIL LEVEL SECTION Oil foaming or boiling over vat • Water in oil • At end of a Cook Cycle, drain and clean vat; add fresh oil • Improper or bad oil • Use recommended oil • Improper filtering...
  • Page 10 Model LVE-202, 203, 204 Problem Cause Correction FILTER MOTOR SECTION • Tighten filter line connections Filter motor runs but • Filter line connections pumps oil slowly loose • Drain pan o-rings damaged • Install new o-rings or missing • Change filter paper or pad • Filter paper or pad clogged Filter motor will not run •...
  • Page 11 Model LVE-202, 203, 204 1-4. ERROR CODES In the event of a control system failure, the digital display shows an error message. The message codes are shown in the DISPLAY column below. A constant tone is heard when an error code is displayed, and to silence this tone, press any button.
  • Page 12 Model LVE-202, 203, 204 1-4. ERROR CODES (Continued) DISPLAY CAUSE CORRECTION Programming failure Turn switch to OFF, then back to ON; if display “E-41” , shows any of these error codes, re-initialize the “E-46” controls; if error code persists, check control...
  • Page 13: Section 2. Info, Filter & Temp Button Stats

    Model LVE-202, 203, 204 SECTION 2. INFO, FILTER & TEMP BUTTON STATS 2-1. INFO BUTTON STATS Recovery Information for each Vat/OQM Information 1. Press and release and REC shows in left display and the recovery time that oil temperature went from 250°F (121°C) to 300°F (149°C) shows in the right display.
  • Page 14: Hp Info Mode

    Model LVE-202, 203, 204 Actual Oil Temperature 1. Press and actual oil temperature shows in display, for each vat. Set-point Temperature 2. Press twice and SP shows in the display, along with the set-point (preset) temperature of each vat. Cook Cycles Remaining before Filtering 2-4.
  • Page 15: Section 3. Level 1 Programming

    Model LVE-202, 203, 204 SECTION 3. LEVEL 1 PROGRAMMING Level 1 contains the following: • Modify product settings • Set the AIF clock for products • Perform the Deep Clean procedure • Fryer Setup Mode 3-1. MODIFYING PRODUCT 1. Press and hold...
  • Page 16 Model LVE-202, 203, 204 3-1. MODIFYING PRODUCT 8. Press and release button and “TEMP” shows in the SETTINGS (Continued) display, along with the preset temperature on the right side of the display. Press the product buttons change the temperature. The temperature range is 190°F (88°C) to 380°F (193°C).
  • Page 17: Aif Clock

    Model LVE-202, 203, 204 3-2. AIF CLOCK This feature allows the controls to be set for periods of the day that block the automatic “Filter Now” prompts. For example, the controls could be set to not interrupt with “Filter Now”...
  • Page 18: Deep Clean Mode

    Model LVE-202, 203, 204 3-2. AIF CLOCK In 12-hour clock mode, there are three items on each line: the start time “XX:XX”, the A or P (am/pm) setting, and the “XX” duration. (Continued) Use the and buttons to set these items, which flashes when the item is selected. To set a new start time setting, use the product buttons, to enter the new value.
  • Page 19: Fryer Setup

    Model LVE-202, 203, 204 3-4. FRYER SETUP This mode has the same settings as seen upon initial start-up of the fryer. 1. Press and hold buttons until LEVEL - 1 shows in the display, followed by ENTER CODE. 2. Enter code 1, 2, 3, 4 (first 4 product buttons). “PROD- UCT”...
  • Page 21: Section 4. Level 2 Programming

    Model LVE-202, 203, 204 SECTION 4. LEVEL 2 PROGRAMMING Used to access the following: • Advanced changes to product settings • Error code log • Password programming • Alert Tone/Volume • No. of cook cycles before filter is suggested • Automatic filter time 1. Press and hold buttons until LEVEL - 2 4-1.
  • Page 22: E-Log (Error Code Log)

    Model LVE-202, 203, 204 4-1. ADVANCED PRODUCT 8. Press button until “FULL HT” shows in display along SETTINGS (Continued) with full heat value in seconds, which means the heat is on as soon as a timer button is pressed, for programmed length of time.
  • Page 23: Passwords

    Model LVE-202, 203, 204 4-3. PASSWORDS The 4-digit passwords can be changed for access to Set-Up, Usage, Level 1, Level 2, & Get Mgr.) 1. Press and hold buttons until LEVEL - 2 shows in the display, followed by ENTER CODE.
  • Page 24: Filter After

    Model LVE-202, 203, 204 The number of cook cycles between filtering the oil can easily 4-5. FILTER AFTER be programmed for all products. 1. Press and hold buttons until LEVEL - 2 shows in the display, followed by ENTER CODE. 2. Enter code 1, 2, 3, 4 (first 4 product buttons). “PROD” and “COMP” show in the displays. 3. Press button 4 times and “FILR AFTR”...
  • Page 25: Section 5. Level 3 Programming

    Model LVE-202, 203, 204 SECTION 5. LEVEL 3 PROGRAMMING Used to access the following: • TECH RESETS-Reset Recovery Faults/Passwords to defaults • SPCL PROG-Program filter control parameters and other items • CLOCK SET-Set the time-of-day clock / calendar • DATA COMM-Data Communications, LonWorks, MMC, etc • HEAT CTRL-Program heat algorithm control parameters •...
  • Page 26: Special Programming

    Model LVE-202, 203, 204 5-2. SPECIAL PROGRAMMING The Special Program Mode is used to set more detailed program- ming, such as: SP-1 • ZONE - USA or Non-USA (default setpoints) SP-2 • System Initialization SP-3 • 2nd Language: English, French, Candian- French, German, Spanish, Portuguese, Swedish, Russian, &...
  • Page 27 Not all Special Program Mode functions are discussed in this section. To ensure proper operation of fryer, please consult Henny Penny Corp. before changing any of these settings. For information on these functions, contact the Service Department at 1-800-417- 8405, or 1-937-456-8405.
  • Page 28 Model LVE-202, 203, 204 5-2. SPECIAL PROGRAMMING 2nd Language (SP-3) 6. Press button and “SP-3 2ND LANGUAGE” scrolls in (Continued) left display. Use buttons to set to: ENGLISH; FRANCAIS; CAN FREN; ESPANOL; PORTUG; DEUTSHE; SVENSKA; РУССКИИ or -NONE-. By setting a second language in the controls, 2 languages...
  • Page 29 Model LVE-202, 203, 204 5-2. SPECIAL PROGRAMMING Edit Unit Serial Number (SP-8) 11. Press button and “SP-8 S/N √ EDIT” shows in left (Continued) display. Press the right √ button to enter the unit’s serial number in the controls, using the product buttons.
  • Page 30: Clock Set

    Data communications and heat controls settings are shown in Level 3 Program Mode. But, to ensure proper operation of fryer, please consult Henny Penny Corp. before changing any of these settings. For more information on these functions, contact Service Department at 1-800-417- 8405, or 1-937-456-8405.
  • Page 31: Tech Mode

    • Total Initialization Not all Tech Mode functions are discussed in this section. To ensure proper operation of fryer, please consult Henny Penny Corp. before changing any of these settings. For more information on these functions, contact Service Department at 1-800-417- 8405, or 1-937-456-8405.
  • Page 32 Model LVE-202, 203, 204 5-5. TECH MODE (Continued) . To enter the TECH Mode, press and hold buttons for 5 seconds, until display shows ”LEVEL 3”, followed by “ENTER CODE”. 2. Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons). “A. TECH” & “RESETS” show in the displays.
  • Page 33 Model LVE-202, 203, 204 5-5. TECH MODE (Continued) T-8 - LED’S TEST Press any of the product buttons numerous times to view each LED across the control panel. T-17 - INPUTS - HDE H = HIGH LIMIT - If “H” is present, the high limit is good.
  • Page 34 Model LVE-202, 203, 204 5-5. TECH MODE (Continued) T-18 - AIF INFO (Continued) If the right control is unplugged, then the left control would show “1 OF 2” instead of “1 OF 3”. Press button and “INP E_P_” & “JL_R_DT_” shows in displays.
  • Page 35 Model LVE-202, 203, 204 5-5. TECH MODE (Continued) T-20 - PUMPS & VALVES (Continued) Press to open and close the RTI discard valve (display shows “DISCARDo” when open) Press to open and close the RTI JIB fill valve (display shows “JIBFILLo” when open) Press and “SEL-VALV” “AT HOME” shows in the dis- plays.
  • Page 36: Stats Mode

    Model LVE-202, 203, 204 5-5. TECH MODE (Continued) T-20 - PUMPS & VALVES (Continued) Press to turn off and on the FILTER light (display shows “FLT*” when on) Press to turn off and on the JIB LOW light (display shows “JLO*”...
  • Page 37: Section 6. Information Mode

    Model LVE-202, 203, 204 SECTION 6. INFORMATION MODE 6-1. INFO MODE This mode gathers and stores historic information on fryer and operator’s performance. Press and hold for 3 seconds, until *INFO* *MODE*” shows on the displays. buttons to access steps and press √ button Press to view the statistics within each step.
  • Page 38 Model LVE-202, 203, 204 6-1. INFO MODE LAST LOAD Press √ button to select Last Load (ex: -P1- = Product (Continued) 1;”L1” = left, 1st product) and press buttons to view the following: FUNCTION DISPLAY EX: Product (Last product cooked) PRODUCT...
  • Page 39: Maintenance Hints

    Model LVE-202, 203, 204 SECTION 7. MAINTENANCE 7-1. INTRODUCTION This section provides checkout and replacement procedures, for various parts of fryer. Before replacing any parts, refer to Troubleshooting Section to aid you in finding the cause of the malfunction. 7-2. MAINTENANCE HINTS 1. A multimeter will help you to check electric components.
  • Page 40: Control Panel And Menu Card Replacement

    Model LVE-202, 203, 204 7-4. CONTROL PANEL & Should the control panel become inoperative, or the menu card MENU CARD needs changed, follow these instructions: REPLACEMENT Control Panel Replacement 1. Remove electrical power supplied to the vat. To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 41: High Temperature Limit System

    Model LVE-202, 203, 204 7-5. HIGH TEMPERATURE A thermocouple is attached to each element and senses oil LIMIT SYSTEM temperature. If temperature exceeds 425°F (218°C), a switch opens and shuts off heat to vat, and an E-10 error code is dis- played.
  • Page 42 Model LVE-202, 203, 204 Checkout: (Continued) 7-5. HIGH TEMPERATURE LIMIT SYSTEM °F Table 8. Type J Thermocouple -- thermoelectric voltage as a function of temperature (°F); reference junctions at 32°F °F °F Thermoelectric Voltage in Milivolts Oil temperature must be below 380°F (193°C) to perform this check.
  • Page 43: Electric Heating Element

    Model LVE-202, 203, 204 7-6. ELECTRIC HEATING The fryers are equipped with as few as 2 heating elements or as ELEMENT many as 8 elements. If one of the small elements in the middle needs replacement, 1 or 2 of the other elements must also be removed to gain access to the faulty element.
  • Page 44 Model LVE-202, 203, 204 7-6. ELECTRIC HEATING Replacement (continued) ELEMENT 6. Remove element sense switch arm from heater pin and (Continued) separate heater from pivot blocks. 7. Using 3/8” socket, remove nut and ground wire from stud. 8. Disconnect 3 heater wires from corresponding contactor in controls area behind control panels.
  • Page 45: Breakers

    Model LVE-202, 203, 204 7-6. ELECTRIC HEATING ELEMENT(Continued) There are two breakers on the electric fryer which protect the filter 7-7. BREAKERS pump. To reset the breaker, open the left door and push up on the plunger of the tripped breaker. To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 46: Main Power Switch

    Model LVE-202, 203, 204 7-8. MAIN POWER SWITCH This is a covered rocker switch, which in the ON position, sends power to all the controls and filter motor. However, in some installations, one pair of contacts may be used to control an exhaust hood fan. To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 47 Model LVE-202, 203, 204 7-9. TEMPERATURE PROBE Checkout: REPLACEMENT (Continued) To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1. Support control panel bottom with 1hand, loosen retaining screw at panel top, slide panel down slightly to clear screw, push panel bottom up, then swing panel top out and down.
  • Page 48 Model LVE-202, 203, 204 7-9. TEMPERATURE PROBE 8. Place nut and new ferrule on new oil level probe and insert probe into compression fitting. REPLACEMENT (Continued) 9. Follow probe installation instructions below: Excess force will damage temperature probe. Hand-tighten nut and then 1/2 turn with a wrench.
  • Page 49: Element Sense Switch

    Model LVE-202, 203, 204 7-10. ELEMENT SENSE This switch removes power to the element when the element is SWITCH raised. If a constant “E-31” “HEATING ELEMENTS ARE UP”, is shown on display when elements are lowered into vat, check element safety switch.
  • Page 50: Contactors

    Model LVE-202, 203, 204 7-11. CONTACTORS The open fryer requires two switching, 24V contactors per vat: a primary and a heat contactor. The primary contactor energiz- es (contacts close) any time the main power switch is in the ON position, and the temperature of the shortening is below 420° F ( 215°...
  • Page 51 Model LVE-202, 203, 204 7-11. CONTACTORS (Continued) 4. With power reapplied and in a heat-up mode, check the power going to both contactor coils. Power should be going to both contactors. If no voltage is found going into the primary contactor coil, check wiring, high limit module, and element switch.
  • Page 52: Selector Valve

    Model LVE-202, 203, 204 7-12. SELECTOR VALVE All vats are plumbed into the selector valve. It controls the flow of oil into and out of each vat. It is a rotary valve oper- ated by a low voltage motor. To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 53 Model LVE-202, 203, 204 7-12. SELECTOR VALVE Switches Replacement (Continued) To avoid electrical shock or property damage, move power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1. Using a 1/8” Allen wrench, loosen 2 screws and remove chain guard.
  • Page 54 Model LVE-202, 203, 204 7-12. SELECTOR VALVE Valve Assembly Replacement (Continued) To avoid electrical shock or property damage, move power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1. Drain oil from all vats.
  • Page 55: Drain Valves

    Model LVE-202, 203, 204 7-13. DRAIN VALVES Replacement Each vat drain valve is opened and closed by an actuator. If oil won’t drain or pump back into a vat, the actuator may be faulty. To avoid electrical shock or property damage, move power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 56: Filter Pump & Motor

    Model LVE-202, 203, 204 7-14. FILTER PUMP & The 2 most common causes for a fryer not to pump oil are that MOTOR the pump is clogged, or the thermal overload switch has been tripped on the motor. The pump and motor is located behind the middle door above the drain pan.
  • Page 57 Model LVE-202, 203, 204 7-14. FILTER PUMP & MOTOR (Continued) To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. Motor Removal: 1. Open the right door and remove JIB from fryer.
  • Page 58 Model LVE-202, 203, 204 7. Using 7/16 in. wrenches, remove 3 nuts, lockwashers, flat 7-14. FILTER PUMP & MOTOR (Continued) washers, spacer washer sets, and bolts securing the motor to the motor bracket. 8. Pull the pump and motor assembly from fryer. 9. Re-install pump and motor assembly following the above steps in reverse order;...
  • Page 59: Jib Pump

    Model LVE-202, 203, 204 This pump keeps the vats filled (Auto Top-Off) 7-15. JIB PUMP Replacement To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1. Disconnect and remove JIB and drain pan.
  • Page 60: Transformers

    Model LVE-202, 203, 204 7-17. TRANSFORMERS These components drop the line voltage to low voltage com- ponents such as, control board, AIF board and contactor coils. Each control transformer is equipped with an integral reset switch. Checkout: To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 61: Filter Motor Relay

    OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1. Disassemble flexible oil lines and fittings from valve as necessary. 2. Apply Loctite Primer (Henny Penny part no. MS01-572) to internal threads of both the inlet and outlet of valve. 3. Reassemble fittings to check valve and install valve and oil lines.
  • Page 62: Drain Pan Switch

    Model LVE-202, 203, 204 7-20. DRAIN PAN SWITCH Switch (P/N 85653) closes when drain pan is properly positioned under fryer. If drain pan is not properly in place, or drain switch is faulty, prompts such as, “CHECK PAN”; “FILTER PAN MISSING”; “CHANGE FILTER PAD” show in display.
  • Page 63: Filter And Jib Lights

    Model LVE-202, 203, 204 7-21. FILTER AND JIB LIGHTS Replacement To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1. Support control panel bottom with 1hand, loosen retaining...
  • Page 64: Oil Level Probes

    Model LVE-202, 203, 204 7-22. OIL LEVEL PROBES The oil level probes monitor the oil level by temperature differences. If they becomes disabled, the display shows: “E-18A”= left probe; “E18-B”= right probe; “E18C”= both. Note that left and right are as viewed from front of fryer.
  • Page 65 Model LVE-202, 203, 204 7. Place connector on flat surface with the open side up. 7-22. OIL LEVEL PROBES (Continued) 8. Hold connector in place with one hand, use other hand to insert pocket knife blade or other small sharp tool into connector notch to depress metal locking tab.
  • Page 66: Manual Operation Of Drain Valve

    Model LVE-202, 203, 204 7-23. MANUAL OPERATION Should the actuation motor of a drain valve cease to operate, OF DRAIN VALVE the drain valve can be operated manually as follows. To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
  • Page 67: Section 8. Parts Information

    Model LVE-202, 203, 204 SECTION 8. PARTS INFORMATION 8-1. INTRODUCTION This section lists the replaceable parts of the Henny Penny Model LVE fryer. 8-2. GENUINE PARTS Use only genuine Henny Penny parts in your fryer. Using part of lesser quality or substitute design may result in damage to the unit or personal injury.
  • Page 68 Model LVE-202, 203, 204 Item No. Part No. Description Quantity 77842 HANGER-BASKET - LVE-202 .......... 77709 HANGER-BASKET - LVE-203 .......... 77934 HANGER-BASKET - LVE-204 .......... 52224 SWITCH - POWER............. 75860 LIGHT - INDICATOR - BLUE ........... 75859 LIGHT - INDICATOR - YELLOW ........
  • Page 69 Model LVE-202, 203, 204 83774 86382 LH Door Assy RH Door Assy without Holder with Holder Model LVE-202 83774 83774 86382 LH Door Assy LH Door Assy RH Door Assy without Holder without Holder with Holder Model LVE-203 83774 83774...
  • Page 70 Model LVE-202, 203, 204 Control Panel Assembly Item No. Part No. Description Quantity 97319 ASSY - CONTROL - LOV ..........1/well** 85378 DECAL - LOV MCD ..........1/control NS02-005 NUT - HEX KEPS #6-32 C ........23/control 26974 ASSY - SPEAKER ............ 1/control 83498 STUD ASSY - CONTROL PANEL COVER ....
  • Page 71 Model LVE-202, 203, 204 Oct. 2010...
  • Page 72 B 16 86306 SEAL-F TO F PIVOT BLOCK (See chart on next page) ..AR 76563 WELD ASSY - SEAM COVER - LVE-202 ......76500 WELD ASSY - SEAM COVER - LVE-203 ......77613 WELD ASSY - SEAM COVER - LVE-204 ......
  • Page 73 Model LVE-202, 203, 204 PIVOT BLOCK PIVOT BLOCK SEAL FRYER MODEL P/N & TYPE P/N & TYPE 202FF 86303 F TO F (end block) 86306 F TO F 203FFF 86303 F TO F (end block) 86306 F TO F 204FFFF...
  • Page 74 Model LVE-202, 203, 204 ELEMENT HARDWARE Oct. 2012...
  • Page 75 Model LVE-202, 203, 204 Item No. Part No. Description Quantity 85777 PUMP & MOTOR ASSY.-60 HZ (See page 8-15 for details) 1 93297 PUMP & MOTOR ASSY.-50 HZ (See page 8-15 for details) 1 MS01-297 CLAMP-HOSE ..............89622-001 HOSE ..................
  • Page 76 Model LVE-202, 203, 204 Oct. 2010 8-10...
  • Page 77 Model LVE-202, 203, 204 Item No. Part No. Description Quantity ME90-008 RELAY - PUMP MOTOR- 12 VDC - 30 AMP ......80728 EMI FILTER - CE ..............EF02-104 FUSE HOLDER - 20A-250V ........... FA52-010 FUSE - 1 AMP (208/240V FRYERS) .........
  • Page 78 Model LVE-202, 203, 204 CENELEC YES/NO Refer to chart below Item No. Part No. Description Quantity 82914 FILTER BOARD - 1P EMC - CE 79596-XXXX GATEWAY - PCB (LONWORKS) see chart below ... Part No. Voltage Transceiver Type Model 79596-1202...
  • Page 79 Model LVE-202, 203, 204 Feb. 2014 8-13...
  • Page 80 Model LVE-202, 203, 204 Item No. Part No. Description Quantity 84372 COVER - REAR SHROUD - LVE-202 .......... 83681 COVER - REAR SHROUD - LVE-203 .......... 86345 COVER - REAR SHROUD - LVE-204 .......... 83034 BRACKET-SWITCH MOUNTING ..........1/vat 83096 SWITCH - ELEMENT LIFT ............
  • Page 81 Model LVE-202, 203, 204 84282-001 84282- VALVE-SELECTOR *The ONLY need for the whole selector valve assembly (84282) to be used for repair would be due to possible shipping damage, fork lift, etc. or damage to the selector valve body ( see the drawing below stainless steel cylinder body in orange ) Desc.
  • Page 82 Model LVE-202, 203, 204 SUCTION TUBE SELECTION CHART VARIANT LEGEND F = Full well - 1 full width shallow vat S = Split well - 2 narrow shallow vats D = Split well - 2 narrow deep vats L = Split well - 2 narrow vats with a deep...
  • Page 83 Model LVE-202, 203, 204 Item No. Part No. Description Quantity 03617 ACCESSORY-JUG-AUTO TOP OFF (EMPTY) .... B 2 85738 ASSY-JIB TUBE & QUICK DISC ........151694 ASSY-RUSSIAN JIB TUBE ........... 85737 ASSY-INT’L. JIB TUBE & QUICK DISC ..... A 2* MS01-561 O-RING - JIB TUBE ..........
  • Page 84 ASSY - DRAIN PAN - LVE ..........85650 ASSY-DRAIN PAN COVER ........85507 WELD ASSY-CRUMB CATCHER ......85503 WELD ASSY-FILTER WEIGHT ......03190-054 McD’s FILTER KIT (not supplied by Henny Penny)..(includes fryer cleaner, 30 filter pads, & green cleaner pads) 85519 FILTER-SECTION ............ 84652 WELD ASSY-DRAIN PAN ........86349 O-RING-PICKUP TUBE ...........
  • Page 85 Model LVE-202, 203, 204 Filter Motor and Pump Item No. Part No. Description Quantity A 1 67583 MOTOR, 1/2 HP - 60 Hz ..........A 1 92850 MOTOR, 1/2 HP - 50 Hz - CE ......... A 2 17476 SEAL KIT ................
  • Page 86 Model LVE-202, 203, 204 Oil Disposal Plumbing-France Item No. Part No. Description Quantity 77523-004 TUBE-SUCTION-30IN-FLEXIBLE ....... FP01-242 FITTING-1/2 NPT M TO 45 FLARE M ......FP01-066 COUPLING 1/2 NPT SS ..........17407 CONNECTOR 1/2 MAIL ELBOW ........ 84288 ASSY-PLUG & PLAY (TO PUMP INLET) ....
  • Page 87 Model LVE-202, 203, 204 Oil Disposal Plumbing-Australia Item No. Part No. Description Quantity FP01-217 COUPLE-REDUCE 1 F X 1/2F BI ........ 77523-004 TUBE-SUCTION-30 IN-FLEXIBLE ......17407 CONNECTOR 1/2 MAIL ELBOW ......... 84288 ASSY-PLUG & PLAY (TO PUMP INLET) ....FP01-245 FITTING-PIPE BRANCH TEE-MALE ......
  • Page 88 Model LVE-202, 203, 204 Fry Cap Item No. Part No. Description Quantity 03618 ACCESSORY-FRY CAP - LVE-202 ....... 03619 ACCESSORY-FRY CAP - LVE-203 ....... 1 03620 ACCESSORY-FRY CAP - LVE-204 ....... Jan. 2011 8-22...
  • Page 89 Model LVE-202, 203, 204 05160004 Oil Quality Monitoring (OQM) Sensor Item No. Part No. Description Quantity 154103 CLAMP, SENSOR OQM............. 154101 ASSY, OQM SENSOR & TUBE ..........154104 SEAL, SENSOR OQM ..............154102 WELD ASSY, OQM SENSOR BODY ........FP01-337 ELBOW-45 DEG 8 SAE ORB X 8 SAE ........
  • Page 90: Wiring Diagrams

    Model LVE-202, 203, 204 APPENDIX A. WIRING DIAGRAMS AND SCHEMATICS WIRING LEGEND The legend below helps in identifying the components of the wiring diagrams on the following wiring diagrams. May 2016...
  • Page 91 Model LVE-202, 203, 204 May 2016...
  • Page 92 Model LVE-202, 203, 204 May 2016...
  • Page 93 Model LVE-202, 203, 204 May 2016...
  • Page 94 Model LVE-202, 203, 204 May 2016...
  • Page 95 Model LVE-202, 203, 204 May 2016...
  • Page 96 Model LVE-202, 203, 204 May 2016...
  • Page 97 Model LVE-202, 203, 204 May 2016...
  • Page 98 Model LVE-202, 203, 204 May 2016...
  • Page 99 Model LVE-202, 203, 204 May 2016 A-10...
  • Page 100 Model LVE-202, 203, 204 May 2016 A-11...
  • Page 101 Model LVE-202, 203, 204 May 2016 A-12...
  • Page 102 Model LVE-202, 203, 204 May 2016 A-13...
  • Page 103 Model LVE-202, 203, 204 May 2016 A-14...
  • Page 104 Model LVE-202, 203, 204 May 2016 A-15...
  • Page 105 Model LVE-202, 203, 204 May 2016 A-16...
  • Page 106 Model LVE-202, 203, 204 May 2016 A-17...
  • Page 107 Model LVE-202, 203, 204 May 2016 A-18...
  • Page 108 Model LVE-202, 203, 204 May 2016 A-19...
  • Page 109 Model LVE-202, 203, 204 May 2016 A-20...
  • Page 110 Model LVE-202, 203, 204 May 2016 A-21...
  • Page 111 Model LVE-202, 203, 204 May 2016 A-22...
  • Page 112 Model LVE-202, 203, 204 May 2016 A-23...
  • Page 113 Model LVE-202, 203, 204 Plumbing Diagram May 2016 A-24...

This manual is also suitable for:

Lve-204Lve-203

Table of Contents