Problem
Oil will not heat
(Continued)
too slow
Oil heating
Oil overheating
Oct. 2010
Cause
HEATING OF SHORTENING SECTION (Continued)
•
Drain valve open
•
Possible faulty temperature probe
•
Faulty contactor
• Breaker on fryer tripped
• Low or improper voltage
• Weak or burnt out element(s)
• Points in contactor bad
• Wire(s) loose
• Burnt or charred wire
connection
• Programming wrong
• Faulty PC board
• Faulty temperature probe
• Check contactor for not
opening
•
Close drain valve
•
Replace temperature probe
•
Check contactor per maintenance
section on contactors
• Check breakers on fryer per
maintenance section on breakers
• Use a meter and check the
receptacle against data plate
• Check heating element(s) per
Element Replacement Section
• Check contactor per
Contactor Replacement Section
• Tighten
• Replace wire and clean
connectors
• Check temperature setting
in the program mode
• Replace control board if heat
indicator stays on past ready
temperature
• Check probe calibration and
replace if temperature is off + 5
degress
• Check faulty contactor per
Contactor Replacement Section
1-4
Model LVE-202, 203, 204
Correction