Henny Penny LVE-202 Technical Manual page 51

Split vat & full vat open fryers – electric
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

7-11. CONTACTORS
(Continued)
Oct. 2010
4. With power reapplied and in a heat-up mode, check the
power going to both contactor coils. Power should be
going to both contactors.
If no voltage is found going into the primary contactor coil,
check wiring, high limit module, and element switch.
If no voltage at heat contactor coil check wiring and
connections at PC board.
Replacement
If either contactor proves defective, replace as follows:
To avoid electrical shock or property damage, move
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Label and remove only those wires directly connected to
the contactor being replaced.
2. Using a 3/8" wrench or socket, remove 2 mounting nuts
on base plate of contactor being replaced and remove
contactor.
3. When replacing the heat contactor, slide it from the
mounting rail.
4. Install new contactor in reverse order.
5. Reconnect power to the fryer and test for proper operation.
6. Support control panel bottom with 1 hand, swing panel
top up about 90 degrees, slide panel down slightly to clear
screw head, push panel top up to engage screw, then tighten
screw.
7-13
Model LVE-202, 203, 204

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lve-204Lve-203

Table of Contents