7-9. TEMPERATURE PROBE
REPLACEMENT
(Continued)
Oct. 2010
8. Place nut and new ferrule on new oil level probe and insert
probe into compression fitting.
9. Follow probe installation instructions below:
Excess force will damage temperature probe. Hand-tighten
nut and then 1/2 turn with a wrench.
10. With locking tab up, insert pin into connector opening and
visually check that tab is fully engaged. Fasten connector
to control panel.
11. Support control panel bottom with 1 hand, swing panel top
up about 90 degrees, slide panel down slightly to clear
screw head, push panel top up to engage screw, then tighten
screw.
12. Reconnect power to vat and fill vat with oil.