Henny Penny LVE-202 Technical Manual page 11

Split vat & full vat open fryers – electric
Hide thumbs Also See for LVE-202:
Table of Contents

Advertisement

1-4. ERROR CODES
DISPLAY
"E-4"
Control board overheating
Oil overheating
"E-5"
Temperature probe open
"E-6A"
Temperature probe shorted checked
"E-6B"
"E-10"
E-10A- tripped above 300F
E-10B- tripped below 300F
E-10C- tripped while cooking
E-10D- tripped <5min. of Auto Filter
E-10F- tripped during filter cycle
E-10M- tripped during melt mode
E-10Y- tripped <5min of "YES" to
"IS THE POT FULL?" prompt
Drain valve open
"E-15"
Left level sensor open
"E-18-A"
Right level sensor open
"E-18-B"
Both level sensors open
"E-18-C"
Slow heat recovery
"E-21"
"E-22"
No heat
"E-31"
Elements are up
May 2016
In the event of a control system failure, the digital display shows an error
message. The message codes are shown in the DISPLAY column below. A
constant tone is heard when an error code is displayed, and to silence this
tone, press any button.
CAUSE
1-7
CORRECTION
Turn switch to OFF position, then turn switch
back to ON; if display shows "E-4", the control
board is getting too hot; check the louvers on
each side of the unit for obstructions
Turn switch to OFF position, then turn switch
back to ON; if display shows "E-5", the heating
circuits and temperature probe should be checked
Turn switch to OFF position, then turn switch
back to ON; if display shows "E-6A", the
temperature probe should be checked
Turn switch to OFF position, then turn
switch back to ON; if display shows "E-6B",
temperature probe should be
Allow fryer to cool for 15-20 minutes; reset high
limit by pressing down & releasing raisedside
of the switch for the vat that is not operating; a
single reset switch is found behind the door of
each well; if high limit does not reset, high limit
must be replaced
Clean and/or close fish vat drain valve; if clean
and closed, have drain switch continuity checked
Turn switch to OFF position, then turn switch
back to ON; If display still indicates a failed
sensor, check the connectors at the control board;
check sensor & replace, if necessory
Have a certified service technician check the fryer
for correct gas supply and pressure to the unit;
have the gas valves checked; have unit checked
for loose or burnt wires
Check power cord and have heat circuit checked
Lower elements back down
Model LVE-202, 203, 204

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lve-204Lve-203

Table of Contents