5-5. TECH MODE (Continued)

5-6. STATS MODE

Oct. 2010
T-20 - PUMPS & VALVES (Continued)
Press
to turn off and on the FILTER light (display shows "FLT*"
when on)
Press
to turn off and on the JIB LOW light (display shows
"JLO*" when on)
This mode allows a technician to view advanced information on the
operation of the fryer and controls.
1. To enter the TECH Mode, press and hold
buttons for 5 seconds, until display shows "LEVEL 3",
followed by "ENTER CODE".
2. Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons). "A.
TECH" & "RESETS" show in the displays.
3. Press
6 times, and when display shows "G. STATS", press
right √ button and "ST-1 LAST RESET ON..." shows in the
display, first step of the TECH Mode. Use and
buttons to toggle through the steps.
ST-1
• Stats Last Reset Date
ST-2
• Fryer Total Running Hours
ST-3
• Left Vat Melt Cycle Hours
ST-4
• Left Vat Cook Cycle Hours
ST-5
• Left Vat Filter Lockout Hours
ST-6
• Right Vat Melt Cycle Hours
ST-7
• Right Vat Cook Cycle Hours
ST-8
• Right Vat Filter Lockout Hours
ST-9
• Power-Ups Count
ST-10
• Errors Count
ST-11
• Left Vat Heat On Hours
ST-12
• Right Vat Heat On Hours
ST-13
• Highest Left Vat Oil Temperature
ST-14
• Highest Right Vat Oil Temperature
ST-15
• Highest CPU Temperature
ST-16
• System RAM Fade Count
ST-17
• Cook RAM Fade Count
ST-18
• Product RAM Fade Count
ST-19
• Stat RAM Fade Count
ST-20
• RAM Data Error Count
ST-21
• Data Total Loss Count
ST-22
• User Intializations Count
ST-23
• Automatic Initializations Count
ST-24
• Cook Counts per Product
ST-25
• Cook Cycle Stop Counts
- "A" = no. of stops in 1st 30 sec.; - "B" = 0; - "C" = 0;
- "D" = complete cook cycles counted
ST-26
• Reset All Stats