Cr_Hp Sensor; Cr_Hp Sensor Removal - Epson Stylus Pro 4400 Service Manual

Hide thumbs Also See for Stylus Pro 4400:
Table of Contents

Advertisement

EPSON Stylus Pro 4400/4450/4800/4880/4880C

4.2.7.5 CR_HP Sensor

1.
Remove "Cover, Side, Right" (p217).
2. Move "Carriage Unit" to center of printer.
(Refer to "4.2.4.3 C593_SUB Board" (p234).)
3. Release "CR_HP Sensor" harness from clamp.
4. Unfasten the two upper hooks securing "CR_HP Sensor", release the
lower tab and then release "CR_HP Sensor".
5. Disconnect the connector from "CR_HP Sensor".
After installing the "CR_HP Sensor", wrap the harness
around the outside as shown in
Disassembly & Assembly
Figure
4-92.
Disassembly Procedures
Clamp
Connectoror
1
2
CR_HP Sensor
Figure 4-92. CR_HP Sensor Removal
Revision C
Wrap around
1
Tabs
276