When performing the following steps, be careful of the
C A U T I O N
points below.
Do not lose "Extension Spring, 0.262".
Use care not to pull "Extension Spring, 0.262" too much,
or it may loose the spring force.
Do not touch the "Cleaner, Head" or allow it to contact
other parts. (This could lower print quality due to not
wiping ink normally.)
7. While keeping the sheet turned aside, remove "Extension Spring, 0.262"
from the tabs of "Mount Assy., Plate, Motor, ASF, SP" and "Lever, Lock,
DE".
(Refer to Figure 4-156.)
8. Pull the "Lever, Lock, Planetary" toward the outside of the printer, release
the hook on top and then pull out of the "Lever, Lock, DE".
(Refer to Figure 4-157.)
After installing the "Lever, Lock, Planetary", confirm that
"Lever, Lock, DE" moves smoothly by the tension of
"Extension Spring, 0.262". (Check three times.)
Disassembly & Assembly
Cleaner, Head
Disassembly Procedures
Extension Spring, 0.262
Tads
Figure 4-156. Extension Spring, 0.262 Removal
Lever, Lock, Planetary
Figure 4-157. Lever, Lock, Planetary Removal