EPSON Stylus Pro 4400/4450/4800/4880/4880C
4.2.7.7 PG Phase Sensor
1.
Remove "Cover, Side, Left" (p216).
2.
Remove "Cover, Side, Right" (p217).
As the PG Cam (Bush, Shaft, Rear) and PG Detection Shield
C H E C K
P O I N T
Plate operate simultaneously, the shield plate can be rotated
by rotating the PG Cam.
3. Rotate the PG Cam manually so that the PG Lock Lever enter the groove
at the extream end of the PG Cam as shown in
releases the shield plate from the "PG Phase Sensor".
(Refer to Figure 4-96.)
Disassembly & Assembly
Figure
4-96. Doing so
Disassembly Procedures
PG Cam
Shield Plate
Figure 4-96. Rotating the Shield Plate
Revision C
PG Lock Lever
Detection Section